Wuhan Guide EasIR-4 Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
User Manual
1
Introduction
This publication provides the necessary information required to safely operate the EASIR
TM
-4 Thermal Camera.
It is important to fully check all equipment with which you have been supplied.
The equipment should be used, maintained and serviced by suitably trained personnel, capable of carefully following
the procedures and guidelines given in this User Manual.
All User Manuals and leaflets should be read thoroughly before proceeding with operation of the equipment.
It is also advisable that all User Manuals and Instruction Leaflets supplied are kept readily available, for reference when
the equipment is in general use.
Precautions
The following precautions must be adhered to at all times and must be considered in addition to any advised
precautions issued at the relevant worksite or work area.
Keep the EASIR
TM
-4 Thermal Camera steady during operation.
Do not use the EASIR
TM
-4 Thermal Camera in temperature exceeding its working and storage temperature
ranges.
Do not direct the EASIR
TM
-4 Thermal Camera at very high intensity radiation sources such as the sun,
carbon dioxide lasers or arc welders etc.
Do not expose the EASIR
TM
-4 Thermal Camera to dust and moisture. When operating the unit near water,
ensure that the unit is adequately guarded against splashes.
When the EASIR
TM
-4 Thermal Camera is not in use or is to be transported, ensure that the unit and its
accessories are stored in the protective carry case.
Do not jam the holes or loudspeaker on the camera body.
Do not re-switch on the camera until 15 seconds later after switching it off.
Do not throw, knock or vibrate intensely the camera and its components in order to keep them from damage.
Do not attempt to open the camera body, as this action will void the warranty.
Keep the SD memory card for the exclusive use of the camera.
During using, if move the IR camera from hot/cold place to cold/hot place, e.g. from inside/outside to
outside/inside of a air-conditioned car in winter, should power off the camera firstly and leave it in the
operation site for 20 minutes, then power on the camera for normal operation and accurate temperature
measurement. Sharp and instant ambient temperature change may cause fault temperature measurement
and even damage camera’s IR detector.
FPA setting: to ensure accurate temperature measurement, the FPA detector was calibrated in different
temperature points--7degree, 17degree, 27degree, 37degree. When power on the camera in 0 degree for
example, after period of working the temperature of the camera (the detector) will increase gradually. And
when the internal temperature of the camera beyond 7 degree, FPA setting will take place and will last for
about 30sec, and during the FPA setting the camera will not response for any operations. If power on the
camera in a temperature about 8 degree, only when the temperature of the camera beyond 17degree, this
phenomenon will happen again. Camera will adjust FPA setting itself automatically to ensure its stable
performance.
Vista de pagina 3
1 2 3 4 5 6 7 8 9 ... 27 28

Comentarios a estos manuales

Sin comentarios